Utilization of the bicipital groove axis for confirming alignment of the humerus with transepicondylar and ulnar shaft axes during intramedullary nailing.

Basit öğe kaydını göster

dc.contributor.author Meriç, Gökhan
dc.contributor.author Zeybek, Gülşah
dc.contributor.author Kıray, Amaç
dc.contributor.author Atik, Aziz
dc.contributor.author Büdeyri, Aydın
dc.contributor.author Koşay, Can
dc.date.accessioned 2021-06-17T08:31:12Z
dc.date.available 2021-06-17T08:31:12Z
dc.date.issued 2015
dc.identifier.issn 1017-995X
dc.identifier.other 26012940
dc.identifier.uri https://doi.org/10.3944/AOTT.2015.14.0188 en_US
dc.identifier.uri http://openaccess.sanko.edu.tr/xmlui/handle/20.500.12527/220
dc.description.abstract Objective: Intramedullary nailing is the preferred surgical treatment of humerus shaft fractures. The purpose of this study was to investigate the relationship between the bicipital groove and specific anatomical landmarks in achieving correct alignment of the humerus during intramedullary nailing, and to describe these anatomical landmarks.Methods: Thirty (15 right; 15 left) total upper cadaver extremities were used in this study. After the anatomical landmarks were identified and marked, humeral head axis, transepicondylar axis, ulnar shaft axis, bicipital groove axis, and angular measurements of these were obtained.Results: The mean angle between the bicipital groove axis and transepicondylar axis was 48.17°±12.35º (range: 20.10º to 74.6º). The mean angle between the bicipital groove axis and ulna diaphysis axis was 41.82º±11.56 º (range: 17.91º to 68.27º). The mean angle between the humeral head axis and bicipital groove axis was 20.53°±3.90º (range: 11.85º to 31.81º). The mean retroversion angle between the humeral head axis and transepicondylar axis was 27.52±11.37º (range: 4.26º to 49.36º). The mean angle between the humeral head axis and ulna diaphysis axis was 61.73º±12.08º (range: 33.97º to 86.37º). The mean torsion angle was 62.58º±11.28 º (range: 40.74º to 85.74º).Conclusion: Measurement and utilization of the relationship between the bicipital groove, ulna diaphysis and transepicondylar axes may be used for restoring humeral rotation en_US
dc.language.iso English en_US
dc.publisher AVES Yayıncılık en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Utilization of the bicipital groove axis for confirming alignment of the humerus with transepicondylar and ulnar shaft axes during intramedullary nailing. en_US
dc.type Article en_US
dc.relation.journal Acta Orthopaedica et Traumatologica Turcica en_US
dc.identifier.issue 2 en_US
dc.identifier.startpage 184 en_US
dc.identifier.endpage 189 en_US
dc.identifier.volume 49 en_US
dc.contributor.authorID Aydın Büdeyri : 0000-0003-1894-5435 en_US
dc.contributor.sankoauthor Aydın Büdeyri en_US


Bu öğenin dosyaları:

Dosyalar Boyut Biçim Göster

Bu öğe ile ilişkili dosya yok.