dc.contributor.author | Mete, Alper | |
dc.contributor.author | Kimyon, Sabit | |
dc.contributor.author | Saygılı, Oğuzhan | |
dc.contributor.author | Evişen, Alper | |
dc.contributor.author | Pamukcu, Can | |
dc.contributor.author | Çeri, Seda | |
dc.contributor.author | Güngör, Kıvanç | |
dc.date.accessioned | 2021-06-25T11:57:37Z | |
dc.date.available | 2021-06-25T11:57:37Z | |
dc.date.issued | 2016 | |
dc.identifier.issn | 0004-2749 | |
dc.identifier.other | 27626141 | |
dc.identifier.uri | https://doi.org/ 10.5935/0004-2749.20160061 | en_US |
dc.identifier.uri | http://openaccess.sanko.edu.tr/xmlui/handle/20.500.12527/278 | |
dc.description.abstract | Purpose: To investigate the effects of the Valsalva maneuver (VM) on optic disc morphology, choroidal thickness, and anterior chamber parameters. Methods: This prospective observational study included 60 eyes of 60 healthy subjects. The anterior chamber parameters, including central corneal thick-ness (CCT), anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), pupil diameter (PD), axial length (AL), subfoveal and pe-ripapillary choroidal thickness, optic disc parameters, and intraocular pressure (IOP), were measured at rest and during VM. Results: VM did not have any significant influence on AL, subfoveal and peripapillary choroidal thickness, optic disc area, rim area, cup area, cup-to-disc area ratio, vertical cup-to-disc ratio, rim volume, cup volume, and nerve head volume measurements (for all; p > 0.05). IOP and PD significantly increased during VM (for both; p < 0.001). VM significantly decreased CCT, ACD, ACA, and ACV values (for all; p < 0.001). Moreover, the optic nerve cup volume decreased and the horizontal cup-to-disc ratio significantly increased during VM (for both; p < 0.05). Conclusions: VM may cause transient changes in IOP, optic disc morphology, and anterior chamber parameters. | en_US |
dc.language.iso | English | en_US |
dc.publisher | CONSEL BRASIL OFTALMOLOGIA, ALAMEDA SANTOS 1343, 11 ANDAR CJ 1110, CERQUEIRA CESAR, SAO PAULO, SP 00000, BRAZIL | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.title | Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver. | en_US |
dc.type | Article | en_US |
dc.relation.journal | ARQUIVOS BRASILEIROS DE OFTALMOLOGIA | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 209 | en_US |
dc.identifier.endpage | 213 | en_US |
dc.identifier.volume | 79 | en_US |
dc.contributor.authorID | 0000-0002-1712-5163 : Alper Mete | en_US |
dc.contributor.authorID | 0000-0001-9194-9841 : Sabit Kimyon | en_US |
dc.identifier.wos | 0004-2749 | en_US |
dc.identifier.doi | 10.5935/0004-2749.20160061 | en_US |
dc.contributor.sankoauthor | Alper Evişen | en_US |
Gazimuhtar Paşa Bulvarı
No:36
27090
Şehitkamil / GAZİANTEP