Investigation of Bacterial Presence in Cerebrospinal Fluid by Bioimpedance Technique

Basit öğe kaydını göster

dc.contributor.author Denkçeken, Tuba
dc.contributor.author Atak, Cihan
dc.contributor.author Demirbakan, Hadiye
dc.contributor.author Erdoğan, Merve
dc.contributor.author Günel Karadeniz, Pınar
dc.date.accessioned 2021-12-21T10:01:24Z
dc.date.available 2021-12-21T10:01:24Z
dc.date.issued 2020
dc.identifier.issn 2564-7784
dc.identifier.issn 2564-7040
dc.identifier.uri http://openaccess.sanko.edu.tr/xmlui/handle/20.500.12527/631
dc.description.abstract Objective: This study aimed to determine the presence of bacteria and their colony numbers in cerebrospinal fluid (CSF) bybioimpedance measurements at 50 kHz phase angle (PA) and 5 kHz impedance values.Methods: We evaluated the performance of the 18 Gauge probe for detecting several types of bacteria in CSF ex-vivo. Weequally monitored the electrical differentiation between colony numbers. A quantity of 200 µl sterile CSF was used as thestandard in each experiment and was inoculated with 1, 2, 5, and 10 colonies of Coagulase-negative staphylococci, Streptococcus pneumoniae and Acinetobacter baumannii, separately.Results: PA and impedance values of CSF samples were compared with each other concerning different colony numbers. Itwas observed that, varying numbers of colony strains of Acinetobacter baumannii, Coagulase-negative staphylococci, andStreptococcus pneumoniae could be differentiated from sterile CSF using PA and impedance values. Only one colony of the A.baumannii strain could not be distinguished from sterile CSF due to its thin cell wall composition.Conclusion: The bioimpedance probe was time-saving and could detect the presence of bacteria in CSF samples correctly.Moreover, the probe can be used in the rapid detection of bacteria in CSF during real-time examinations. en_US
dc.language.iso English en_US
dc.publisher AVES Yayıncılık en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Investigation of Bacterial Presence in Cerebrospinal Fluid by Bioimpedance Technique en_US
dc.type Article en_US
dc.relation.journal European Journal of Therapeutics en_US
dc.identifier.issue 3 en_US
dc.identifier.startpage 208 en_US
dc.identifier.endpage 214 en_US
dc.identifier.volume 26 en_US
dc.contributor.authorID 0000-0002-4663-5410 : Tuba Denkçeken en_US
dc.contributor.authorID 0000-0003-4180-8201 : Hadiye Demirbakan en_US
dc.contributor.authorID 0000-0003-3768-2351 : Pınar Günel Karadeniz en_US
dc.identifier.doi https://doi.org/10.5152/eurjther.2020.20136 en_US
dc.contributor.sankoauthor Tuba Denkçeken en_US
dc.contributor.sankoauthor Cihan Atak en_US
dc.contributor.sankoauthor Merve Erdoğan en_US
dc.contributor.sankoauthor Hadiye Demirbakan en_US
dc.contributor.sankoauthor Pınar Günel Karadeniz en_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

Gazimuhtar Paşa Bulvarı
No:36
27090
Şehitkamil / GAZİANTEP